AegisSAN LX P600Q-D424 & P600Q-S424 10GbE iSCSI-SAS 4U24 SAN System  





Provide Great Performance & Availability for Enterprises
 
AegisSAN LX P600Q, boasting Intel Xeon processor, is a 10GbE iSCSI, 6G SAS high availability RAID system offering high performance and supporting up to 256 SAS & SATA drives. AegisSAN LX P600Q storage features QiSOE (Qsan hardware iSCSI offload engine) and hardware RAID to boost performance and provide superior IOPS & throughput to process tremendously huge amount of random access data for applications like surveillance, video streaming, backup, etc.

IT Pro award

 

PC Pro Award

   
Dual active RAID controllers, redundant power supplies, fan modules, and battery backup modules as well as JBOD expansion – all these included in Qsan's P600Q make the iSCSI RAID storage a high availability system.
 
For better data protection, the top-notch disk array offers copy-on-write snapshot (QSnap), remote replication (QReplica), and battery backup module (BBM) features. It also delivers multiple paths and load balancing functions such as MPIO, MC/S, Trunking, and LACP to better guarantee the reliability and a robust storage environment.
 
AegisSAN LX P600Q other form factors: 4U 60-Bay, 3U 16-Bay, 2U 12-Bay
AegisSAN LX series: F600Q, P400Q
Aegis SAN iSCSI series: P300Q, P500Q
All Qsan storage systems



 

  1. Two 10GbE + two 1GbE iSCSI ports per controller
  2. High IOPs & throughput performance
  3. Fully redundant & hot pluggable designs: RAID controllers, HDDs, power supplies, fan modules, battery backup modules, & JBOD expansion
  4. Hardware iSCSI offloaded engine
  5. Green storage designs: auto disk spin down, advanced cooling mechanism, & 80 PLUS energy-efficient power supplies
  6. Advanced data protection: RAID 6, 60, QSnap writeable snapshot, QReplica remote replication, Windows VSS support, volume cloning
  7. Flexible volume management for multiple applications & environments: virtualization (VMWare, Hyper-V, Citrix), cloud storage, SQL, Exchange, surveillance, file backup, email, boot from SAN, & etc
  8. High connection availability: load balancing & failover
  9. Extendable capacity up to 256 hard drives

P600Q iSCSI system is specially designed for high availability applications. The P600Q has fully redundant components including redundant RAID controllers, power supplies, fan modules, battery backup modules and SAS JBOD expansion ports. All of these components are hot-swappable to create a high availability platform and provide non-stop services. Special features in firmware are RAID 6, 60 support, QSnap writable snapshot, Windows VSS support, and volume configuration restoration. All these features are designed to add an extra layer of protection to your valuable data. To raise the bar higher, P600Q can upgrade firmware without system down time. Both firmware image and volume handling are well protected by the redundant RAID controllers. When one RAID controller is down or disconnected, the other RAID controller will take over all tasks immediately and seamlessly.

With Qsan's latest hardware architecture design plus powerful Intel® C5500/C3500 series processor, P600Q can top the chart with high IOPs and throughput performance. The best breed of its kind! Stability and performance are the mottos we live up to. P600Q can definitely help you deliver more business outputs with less hardware due to consolidation and reduce your energy footprint significantly.

With much wider pipes for data transmission, you can stretch out to more value-added and profitable applications. Users can install up to?128 OSes?with P600Q system through the Boot-from-SAN feature. P600Q is ideal for the following applications.
  1. Server virtualization : vMotion, clustering
  2. Network convergence in data centers
  3. Cloud computing storage
  4. VDI (virtual desktop infrastructure) applications
  5. Mission critical applications : transaction processing, email, database...etc
  6. Video editing & post processing
  7. IP-based surveillance system : casinos, hospitals, and airports
  8. High performance computing : blade server, medical imaging, astrophysics, meteorology, and oil applications
All P600Q systems are equipped with Qsan’s default green features for power saving. In most cases, the hard drives consume most power. With the auto disk spin down feature and proper configuration, the power consumption of hard drives can be reduced to a minimum, and users will not even notice this feature. P600Q monitors the environment temperature for cooling mechanism and the fan modules respond accordingly. The power supply modules are all 80 Plus Gold power efficient for better power converting rate. In virtue of the reduction of hard drive power consumption, the advanced cooling mechanism, and the energy-efficient power supplies, the unnecessary power cost is decreased greatly.
  P600Q-D424 P600Q-S424
Hardware Components
RAID Controller Dual controllers Single & upgradable controller
No. of Host Channels
Per Controller

2 x 10GbE iSCSI ports
2 x 1GbE iSCSI ports

2 x 10GbE iSCSI ports
2 x 1GbE iSCSI ports

Expansion Enclosure J300Q series J300Q series
Cache Memory
Per Controller
4GB, up to 16GB 4GB, up to 16GB
Processor Intel Xeon Intel Xeon
Drive Connectivity 6Gb/s SAS/SATA/SSD 6Gb/s SAS/SATA/SSD
No. of Hard Drives
(6G, 3G SAS, 6G, 3G SATA)
24 24
Max. No. of Hard Drives
(6G, 3G SAS, 6G, 3G SATA)
256 256
Power Supply 3 x 550W 3 x 550W
Fan 2 2
Dimensions 4U 19” Rackmount
446.0mm x 499.5mm x 176.0mm (W x D x H)
Feature Highlights
Green Auto disk spin down
Advanced cooling mechanism
80 Plus Gold energy-efficient power supplies
Host Interfaces
10GbE iSCSI
iSCSI
Hardware iSCSI offload engine
Jumbo frame
Header/Data digest
CHAP authentication
Virtual LAN
Up to 128 multiple nodes support
Up to 128 hosts support
Up to 1024 sessions per controller
RAID & Volume RAID level 0,1,0+1,3,5,6,10,30,50, 60, JBOD, N-way mirror
Up to 4096 logical volumes
Up to 64 hard drives per volume group
One logic volume can be shared by as many as 16 hosts
Global and dedicated hot spare
Write-through or write-back cache policy
Online volume expansion
Instant RAID volume availability
Auto volume rebuilding
On-line volume migration without system down time
High Availability Dual-active RAID controller
Cache mirroring through high bandwidth channels
Flexible RAID group ownership management
Management port seamless take-over
Online firmware upgrade, no system down time (dual-controller mode only)
Multi-path & load-balancing support (Microsoft MPIO, MC/S, Trunking, LACP)
Advanced Data Protection QReplica remote replication
QSnap writable snapshot
Microsoft Windows Volume Shadow Copy Services (VSS)
Configurable N-way mirror
Online disk roaming
Instant volume restoration
Hot pluggable battery backup module (BBM)
Management QCentral Java-based centralized management software
LCM, Serial console, UPS console, SSH telnet, HTTP Web UI, Secured Web (HTTPS), LED idicators, iSNS, S.E.S.
Notification Email; SNMP trap; Browser pop-up windows; Syslog; Windows Messenger
OS Support Windows Server 2003, Windows Server 2003R2, Windows Server 2008 R2;
Red Hat Enterprise Linux 5; Solaris 10; Mac OS X
Virtualization VMware Ready; Hyper-V; Citrix Ready
Safety / EMI RoHS, CE, FCC, BSMI, UL, cUL
Warranty 3-year warranty for system
1-year warranty for battery backup module
Requirements
AC Input 90 ~ 264V, 47/63Hz, 10A@115V / 5A@230V 550W with PFC (Auto Switching)
DC Output 3.3V-25A; 5V-32A; 12V-40A
Operating Temperature 0 to 40°C
Relative Humidity 5% to 95% non-condensing
Controller Configuration
P600Q-D424 Dual controllers
P600Q-S424 Single & upgradable controller
Optional Components
Host connectors P600Q-DxxxS   SFP+ connector
  P600Q-DxxxT   BaseT(RJ45) connector
  P600Q-DxxxC   CX4 connector
8GB RAM 8GB DDR3 RAM support
6G MUX board For dual controller mode, SATA drives support
 
IT Pro (United Kingdom) SVC award
August, 2013
Qsan's affordable IP SAN appliance has performance, redundancy and expansion high on its agenda.
 
       Privacy Policy  |   Legal Information Copyright © 2004 - 2014 Qsan Technology, Inc. All Rights Reserved.  
 
 

Warning: Unknown: Your script possibly relies on a session side-effect which existed until PHP 4.2.3. Please be advised that the session extension does not consider global variables as a source of data, unless register_globals is enabled. You can disable this functionality and this warning by setting session.bug_compat_42 or session.bug_compat_warn to off, respectively. in Unknown on line 0